- 5.10 -
7. Remove the ink at the wiper and the bracket
using a swab dampened with cleaning fluid RS.
If dirt of curl is serious, replace the wiper with a
new one. At the time of replacement, be sure to
terminate the plotter operation and follow the
wiper replacement procedure.
page 5.5
8. Holding the projections at both ends, insert the
wiper which has cleaned into place.
9. Press the [ENTER] key.
10. Fill the cap with the cleaning fluid using a
dropper.
11. Close the front cover.
12. Press the [ENTER] key.
13. Press the [
] and [ ] key to select the time to
leave. (1-99 mins: 1 min unit)
Normally set 1 min.
STATION
LEAVING : 2 min
Fill the Liquid.
COMPLETED :ent
STATION
LEAVING : 1 min