– 3.23 –
3-4-8. Banding (wind repples)
Problems Banding (wind repples) occur at each scan.
Causes 1) The platen temperature setting is not appropriate. (too low.)
Checking procedures 1) Raise the print-heater temperature to see that no blotting or beading occurs.
2) Raise the print setting (pass) to see that no blotting or beading occurs.
(For some media, the problem of blotting or beading cannot be solved
completely.)
Remedies 1) Raise the print-heater temperature.
After change the temperature of heater, be sure to adjust [MEDIA
COMP.].
2) Change the print setting (pass) to high class.