– 4.25 –
4-2-13. Replacement Fuse
There are two fuses in the instrumentation box.
Both AC lines (phase L/N) to the heater contain one fuse.
These fuses are used commonly to the Printheater and Preheater.
[Replacing procedure]
1) Check whether a fuse has blew.
If a contact can be seen at the display hole of the fuse, it has blew.
Check Fuse
GP75
250V
7.5A
Display hole
Normal
Abnormal
Contact
2) Remove the fuse from the holder and replace it with a new one.