6-31
CHAPTER 6 Operation for Functions Applied settings of functions
Setting the temperatures and standby time of heaters
Set the temperatures and standby time of heaters by the following procedure:
STEPS:
1 Make sure that the printer is in LOCAL mode.
If it is in REMOTE mode, press the [REMOTE] key once.
2 Select [SET UP] using the [FUNCTION] key and press the [ENTER] key twice.
3 Select [HEATER] by pressing the [] key twice and press the [ENTER] key.
4 At this point, either of [SET TEMP.] and [SET TIME] can be selected by pressing the
[] or [] key.
5 Press the [ENTER] key to go to the lower level of hierarchy and input the setting val-
ues of heater temperatures using appropriate ones of the [], [], [] and [] keys.
Use the [] or [] key to change the setting values of temperatures, the [] or [] key to move the cursor,
and the [ENTER] key to register the setting values in memory.
PRE PRT AFT
35°C 40°C 50°C
L. ∗ > [JV5-01]
width : ∗∗∗∗ mm
PRE PRT AFT
35°C 40°C 50°C
FUNCTION
SET UP <ENT>
Twice
PRE PRT AFT
35°C 40°C 50°C
[1]
HEATER <ent>
PRE PRT AFT
35°C 40°C 50°C
[1]
MEDIA COMP. <ent>
Twice
PRE PRT AFT
35°C 40°C 50°C
[1] HEATER
SET TEMP. <ent>
PRE PRT AFT
35°C 40°C 50°C
[1] HEATER
SET TIME <ent>
INPUT RANGE
OFF, 20 - 60 °C
PRE PRT AFT
35°C 40°C 50°C
Input range:
PRE [OFF, 20 - 60] ° C
PRT [OFF, 20 - 60] ° C
AFT [OFF, 20 - 70] ° C
Comentários a estes Manuais