4-40
Checking method of UV illumination intensity
UV lamp is a consumable. The more the irradiation time increases, the more the amount of light decreases
and the ink will become hard to harden. When the cumulative irradiation time exceeds a certain value, a
message prompting you for checking the illumination intensity is displayed on the operation panel.
Check the UV lamp illumination intensity following this operation
manual and use it as a reference when replacing the UV lamp.
Notes when checking the illumination intensity
Notes when checking the illumination intensity
The OPT-J0288 Illumination intensity measuring kit (with illumination meter), or the OPT-J0289 Illumination
intensity measuring kit (without illumination meter) if you have the handy type illumination meter for the
UJF-605C is required.
• Be sure to wear the attached goggle and the gloves.
• Wear long sleeves in order to protect your skin from the UV lamp.