4-43
Checking method of UV illumination intensity
4
How to care
12
Press the key to terminate the
measurement.
• If you press the key, the screen returns to the
Step 9 and measurement is performed again.
• If you wish to measure it again, be sure to leave as
it is for a while and then perform the measurement.
Due to the heat of the UV lamp, you cannot gain the
proper measurement value.
13
When the message on the right is
displayed, open the front left cover.
14
Wait until the illumination meter
bracket is cooled down.
• The time until it is cooled down is displayed.
• When the countdown is completed, the screen changes to the next screen.
15
Return the flushing L cover A to the
original status and press the
key.
(1) Remove the sensor from the rear surface of the
bracket and fix it with the cable clamp.
(2) Return the illumination meter bracket to the original
status.
(3) Press the key.
16
Close the front left cover.
• The illumination meter bracket is heated by the UV lamp immediately after
checking the illumination intensity and if you touch it, you may suffer burns.
Remove the illumination meter bracket after being cooled fully.
UV LEVEL CHECK
CHECK < > F I N I SH
PLEASE OPEN
THE LEFT COVER
UV LEVEL CHECK
AWA I T COOL I NG 0 1 : 3 0
UV LEVEL CHECK
REMOVE A SENSOR : e n t
ENTER
PLEASE CLOSE
THE LEFT COVER