Test drawing
Make test drawing to check blur or missing caused by nozzle clogging.
1
When <LOCAL> is displayed, press the
key.
2
Select [NOZZLE CHECK] with the or
key , and press the key.
3
Test drawing starts.
4
Test drawing ends.
<LOCAL> is displayed.
5
Check the drawing.
When the drawing is normal, data can be printed.
When the drawing is abnormal, execute head cleaning. ( P.2-14)
When needed, adjust the origin position. ( P.3-2)
When the following message is displayed, it cannot print. Start drawing after the message has
disappeared.
“WATER NOT READY” The water temperature in the water heating device has not
reached the predetermined value.
Check before starting
test drawing
Is media set ?
( P.2-11)
Is the origin position set ?
(P.3-2)
Is the head gap value registered? ( P.3-16)
Is the checking method of the gap adjustment set?
(P.3-4)
Is the gap checked? ( P.3-5)
Normal pattern
Abnormal pattern
Many lines are missing
Some lines are missing
in places
Space between lines is
closed or doubled
<LOCAL . 1>
TEST DRAW
NOZ Z L E CHECK < ENT >
ENTER
** TEST DRAW **