4-42
7
Close the front left cover.
8
Press the key to select the UV
illumination intensity and press the
key.
Every time you press the [FUNCTION] key, the UV
illumination intensity will change (HIGH, NORMAL,
LOW).
9
Measure the amount.
10
The measured result is displayed.
11
Press the key to record the
measured UV illumination intensity.
Do not touch the illumination meter bracket during the check of illumination
intensity because it is heated by the UV lamp. You may suffer burns.
PLEASE CLOSE
THE LEFT COVER
UV LEVEL CHECK : H I GH
CHECK START : e n t
UV LEVEL CHECK : NORML
CHECK START : e n t
UV LEVEL CHECK : LOW
CHECK START : e n t
FUNCTION
ENTER
** CHECKING **
PLEASE WA I T
UV LEVEL CHECK
HIGH : * * * * mW
* * RECORD UV LEVEL * *
HIGH : * * * * mW
ENTER