Vista de página 134
4-41
Checking method of UV illumination intensity
4
How to care
Check the UV illumination intensity
1
Turn ON the power supply. ( P.2-4)
2
When <LOCAL> is displayed, press the
key.
3
Select [LEVEL CHECK] with the
key, and press the key.
4
Press the key.
The carriage will move automatically from the
waiting position (left side) to the right side.
5
Remove the screws (on two places)
and the front left cover.
6
Remove the illumination meter bracket
and insert the sensor part into the
square hole on the rear surface.
<LOCAL . 1>
UV
UV LAMP
LEVEL CHECK < e n t >
ENTER
UV LEVEL CHECK
HEAD MOVE : e n t
ENTER
PLEASE OPEN
THE LEFT COVER
Front left
cover